Features of Apollo 2B6K-L 6000VA UPS In Bangladesh
Brand - Apollo, Model - Apollo 2B6K-L 6000VA, Type - Online UPS, Volt Ampere (VA) - 6000V, Input Voltage (V) - 110Vac - 290Vac (Single Phase), Output Voltage (V) - 220Vac, Frequency (Hz) - 50 Hz (60 Hz on request) + - 5% (Input), 50 / 60Hz, + - 0.5% (Output), Transfer Rate (ms) - 0ms, LED Display - Yes, Battery(Qty with V & A) - (Battery Not Included), Waveform - Pure Sinewave, Protection - High Voltage, Overload, Overheating, bypass, Short circuit, Noise Filtering, Spike, Surge. EMI Filter: 10-100 KHz at 40dB, 100KHz-100MHz at 70Db. Alarm - Audio alarm: Keep 90 seconds at a time interval of 4 seconds. Battery Low: Auto shutdown upon complete discharge of battery and auto tum-on upon recovery of utility power. Fault: Continuous alarming. Interface: RS232 / SNMP. Software Management: AC fault, low battery, intelligent software for shutdown by remote control, Transformer Type: Built-in Galvanic Isolation Transformer., Overload Protection - Yes, Surge Protection - Yes, Short Circuit Protection - Yes, Power factor - > 0.98% (Full Load), Crest Factor - 3:01, Body Materials - Metal, Dimension - 585 x 230 x 580mm, Others - Input - Power Factor: > 0.98% (Full Load). Output - Voltage Regulation: 220Vac + - 0.5%. Transient Response: + - 3-4% under full load, change and corrected within 2 ms. Wave Form: Pure Sinewave THD <3%. Power factor: 0.7 - 1 (lagging), Crest Factor: 3:01, Overload: Continuous alarming, switch to bypass, auto recovery upon removing of load, Overload Capacity: <110% load Continuous, 110-125% load 12 Minutes, 125-150% load 10 Minutes, >150% load: by pass. Battery Type: Maintenance free lead-acid batteries. DC Voltage: 192VDC. External Battery: Up to 8 hours long time backup depends on external battery. Recharge time: 5-8 hours. Transfer Time: Zero (0) millisecond, Inverter to Bypass (Overload), Protections: High Voltage, Overload, Overheating, bypass, Short circuit, Noise Filtering, Spike, Surge. EMI Filter: 10-100 KHz at 40dB, 100KHz-100MHz at 70Db. Alarm - Audio alarm: Keep 90 seconds at a time interval of 4 seconds. Battery Low: Auto shutdown upon complete discharge of battery and auto tum-on upon recovery of utility power. Fault: Continuous alarming. Interface: RS232 / SNMP. Software Management: AC fault, low battery, intelligent software for shutdown by remote control, Transformer Type: Built-in Galvanic Isolation Transformer., Warranty - 1 Year (Box Mandatory While Claiming)
What is the price of Apollo 2B6K-L 6000VA UPS In Bangladesh?
The price of Apollo 2B6K-L 6000VA UPS not mentioned for stock unavailability.
The price may vary due to your customization and product availability.
You can buy Apollo 2B6K-L 6000VA UPS from our website or visit our showrooms nearby.